Benefits
- Benefit 1: Keeping Water Clean
- Benefit 2: Strength & Long Term Reliability
- Benefit 3: Sealing Properties And Watertightness
- Benefit 4: Complete Drainage
- Benefit 5: Thermal Insulation Property
- Benefit 6: Environmentally Friendly
- Benefit 7: Re-locability
- Benefit 8: Flexible design and Modular shape
- Benefit 9: Simplicity of Handling and Site Installation
- Benefit 10: Cost Effective Maintenance Free Solution
General Specifications
Manufacturing Process :
Hot Pressed Sheet Moulding Compound (SMC) Compression Moulding
Up To 150 Degree Celsius
Tank Structural Support
- Tie-rod System
External : Hot Dipped Galvanised Steel
Internal : SS304 Tie-rod, Optional SS316* - Roof Support
PVC pipes with GRP roof panel stiffener
*Optional: ABS pipes - External Braced System
External : Hot Dipped Galvanised Steel
Internal : None (metal free inside)
Standard :
Singapore Standard SS245: 2014
Malaysia Standard MS 1390: 2010
similar to British Standard
BS 7491 Part 3:1994 and BS EN 13280:2001
Materials :
Sheet Moulding Compound (SMC) consists of:
- Resin
Isophthalic unsaturated polyester resin conforming to BS 3532 specification - Fibre Glass
Alkali free fibre glass – Type E glass
Sealant :
- Nontoxic PVC foam
- EPDM Rubber
Bolts, Nuts and Washers :
- External
Standard: Hot Dipped Galvanised Steel
*Optional: SS 304/316 - Internal
Standard : SS 304 (In-contact with water)
*Optional: SS 316 (In-contact with water) - Roof
Standard: Hot Dipped Galvanised steel
* Optional: SS 304/316
Water Level Indicator :
- Standard: Reversed Reading
Mechanical Ball Float Type (Cat & Mouse) - *Optional: Direct Reading Clear Tube Type
Ladder :
- External
Standard: Hot Dipped Galvanised Steel, 300mm width - Internal
Standard: PVC or Aluminium, 300mm width
*Optional: GRP or SS 304/316, 300mm width
Nozzle Panel :
- Pipe nozzles flange not inclusive
- Flat panels will be provided upon request
GRP Panel Design
PRE-Insulated Panel
By encapsulating a 25mm ~ 50mm layer of rigid polyurethane foam, POTAGLAS pre-insulated panel could maintain the desired water temperature stored inside the tank under extreme temperature condition. POTAGLAS pre-insulated panel could be selected for water storage where there is a need to stabilize the temperature against extreme heat or freezing conditions so to prevent dew formation.
*Flange height (FH) varies according panel series
*Standard colour: gray
Performance of Panel
CHARACTERISTICS | POTAGLAS GRP TANK PANEL PERFORMANCE | ACCEPTANCE CRITERIA (SS 245:2014 SPECIFICATION) |
---|---|---|
Tensile Strength (MN/m²) | > 103 | >70 (min) |
Bending Strength (MN/m²) | > 171 | > 100 (min) |
Elastic Modulus in Bend (MN/m²) | > 12260 | > 6000 (min) |
Glass Content (%) | > 40 | > 25 (min) |
Barcol Hardness | 57 | >30 (min) |
Water Absorption (%) | 0.1 | 0.5 (max) |
Skid Base Specifications
TANK HEIGHT | MAIN BEAM | SUB BEAM | CONCRETE PLINTH DISTANCE |
---|---|---|---|
1.0m | HDG Hollow Section 50mm x 50mm x 3mm | HDG Hollow Section 50mm x 50mm x 3mm | 1000mm c/c *c/c = centre to centre |
1.5m | HDG Hollow Section 50mm x 50mm x 3mm | HDG Hollow Section 50mm x 50mm x 3mm | 1000mm c/c *c/c = centre to centre |
2.0m | HDG Hollow Section 50mm x 50mm x 3mm | HDG Hollow Section 50mm x 50mm x 3mm | 1000mm c/c *c/c = centre to centre |
2.5m | HDG Hollow Section 50mm x 50mm x 3mm | HDG Hollow Section 50mm x 50mm x 3mm | 1000mm c/c *c/c = centre to centre |
3.0m | HDG Hollow Section 50mm x 50mm x 3mm | HDG Hollow Section 50mm x 50mm x 3mm | 1000mm c/c *c/c = centre to centre |
3.5m | Hollow Section 50mm x 50mm x 4.5mm | Hollow Section 50mm x 50mm x 4.5mm | 1000mm c/c *c/c = centre to centre |
4.0m | Hollow Section 50mm x 50mm x 4.5mm | Hollow Section 50mm x 50mm x 4.5mm | 1000mm c/c *c/c = centre to centre |
*Potaglas reserves the right to provide alternate skid base designs depending on the site condition and material availability.
Internal Tie-Rod Design
MAIN COMPONENTS | EXTERNAL STRUCTURAL SUPPORT | INTERNAL STRUCTURAL SUPPORT | TANK ACCESSORIES |
---|---|---|---|
Top Panel | Body Angle | Pole | Access Manhole |
Side Panel | Corner Angle | Pole Support | Air Vent |
Bottom Panel | – | Tie Rod | Water Level Indicator |
Drain/Pit Panel | Flat Bar | Roof Support | Internal Ladder |
Stay Plate | In Corner Bracket | External Ladder |
External Braced Design
MAIN COMPONENTS | EXTERNAL STRUCTURAL SUPPORT | INTERNAL STRUCTURAL SUPPORT | TANK ACCESSORIES |
---|---|---|---|
Top Panel | Flat Bar | Pole | Access Manhole |
Side Panel | Body Angle | Pole Support | Internal Ladder |
Bottom Panel | – | Roof Support | External Ladder |
Drain/Pit Panel | C-Channel | In Corner Bracket | Air Vent |
Vertical I Beam | Tube Level Indicator | ||
Roof Flat Bar | |||
Side I Beam Support Bracket | |||
External Bracing Support |